Replacement Main Circuit Breaker, 4 Pole, 200 Amp, Type EQ or MBK for an ITE, Gould, Pushmatic or Siemens Panel.
The EQ96 may not directly replace the EQ94 or the EQ-P without modification, as the EQ96 breaker has extended wings by each lug. This extended wing will have to be notched if your panel fingers are not long enough to reach the lugs.
150 Amp, 2 Pole, 240V, 10kAIC, Plug-In Main Circuit Breaker.
Replacement for the following types of plug-in only main breakers: Zinsco, Sylvania, Challenger QFP, Westinghouse WFP, Thomas & Betts TBFP, Unicorn or General Switch GDP, 10K rated, 2 pole breaker.
WARNING: If your main breaker has extended, offset or side entrance lugs "type T, 2T, M or K" this breaker may not work.
30 Amp and 50 Amp, 120/240 Volt, 2 Pole Quad Circuit Breaker, AIC Rating 10.
Equal to one 2 Pole, 30 Amp Breaker and one 2 Pole, 50 Amp Breaker. Takes 2 Plug-In 1-Pole Spaces.
175 Amp, 2 Pole, Plug-In Main Circuit Breaker.
Replacement for the following types of plug-in only main breakers: Zinsco, Sylvania, Challenger QFP, Westinghouse WFP, Thomas & Betts TBFP, Unicorn or General Switch GDP, 10K rated, 2 pole breaker.
WARNING: If your main breaker has extended, offset or side entrance lugs "type T, 2T, M or K" this breaker may not work.
Replacement Main Circuit Breaker, 4 pole, 150 amp, 120V-AC, 240V-AC, Type EQ or MBK for an ITE, Gould, Pushmatic or Siemens Panel.
The EQ96 may not directly replace the EQ94 or the EQ-P without modification, as the EQ96 breaker has extended wings by each lug. This extended wing will have to be notched if your panel fingers are not long enough to reach the lugs.
200 Amp, 2 Pole, Plug-In Main Circuit Breaker.
Replacement for the following types of plug-in only main breakers: Zinsco, Sylvania, Challenger QFP, Westinghouse WFP, Thomas & Betts TBFP, Unicorn or General Switch GDP.
WARNING: If your main breaker has extended, offset or side entrance lugs "type T, 2T, M or K" this breaker may not work.
175 Amp, 4 Pole, Single Phase, 120/240V Circuit Breaker With Lugs. This breaker has an operating handle that moves up for on and down for off.
New replacement breaker for old style GE type THQMV. Breaker base plate snaps into the panel and the lower fingers are secured with 2 nuts to the panel bussing. This is a new breaker removed from a new panel. No manufacturer's box or packaging is included.
Two 1-Pole, 20 Amp and One 2-Pole, 20 Amp,
120/240 Volt, 10kAIC,
Plug-In,
Type BRD,
Type BR Loadcenters,
Includes Rejection Tab Feature,
Non Common Trip.
UL Listed.
All Type BD Duplex and BQ Quadplex circuit breakers carry listing for HACR applications. All 15 and 20 ampere single poles are switch duty rated.
Bryant
Two 2-Pole, 15 Amp,
120/240 Volt, 10kAIC,
Plug-In,
Type BRD,
Type BR Loadcenters,
Includes Rejection Tab Feature.
UL Listed.
All Type BD Duplex and BQ Quadplex circuit breakers carry listing for HACR applications. All 15 and 20 ampere single poles are switch duty rated.
One 2-Pole, 30 Amp and One 2-Pole, 50 Amp,
120/240 Volt, 10kAIC,
Plug-In,
Types BRD & A- A2302115,
Type BR Loadcenters,
Includes Rejection Tab Feature,
Non Common Trip.
UL Listed.
All Type BD Duplex and BQ Quadplex circuit breakers carry listing for HACR applications.
Two 1-Pole, 20 Amp and One 2-Pole, 30 Amp,
120/240 Volt, 10kAIC,
Plug-In,
Types BRD & A- A2302115,
Type BR Loadcenters,
Includes Rejection Tab Feature,
Non Common Trip.
UL Listed.
All Type BD Duplex and BQ Quadplex circuit breakers carry listing for HACR applications. All 15 and 20 ampere single poles are switch duty rated.
Westinghouse
One 2-Pole, 25 Amp and Two 1-Pole, 15 Amp,
120/240V,
Plug-In,
Includes Rejection Tab,
Type BRD,
Inside Poles Common Trip.
UL Listed.
All Type BD Duplex and BQ Quadplex circuit breakers carry listing for HACR applications. All 15 and 20 ampere single poles are switch duty rated.